    摘要:

    采用辅助冷却复合地源热泵系统,可有效地降低初投资,提高系统的节能效果。本文介绍了冬冷夏热地区的气候与建筑能耗概况;对辅助冷却复合地源热泵系统在这个地区可行性进行了理论分析;并针对上海地区某一办公建筑,对比分析了辅助冷却复合地源热泵系统和无辅助冷却地源热泵系统的初投资和运行费用。结果表明,辅助冷却复合地源热泵系统在该地区减少初投资和运行费用方面具有明显的优越性。

    Abstract:

    The initial investment and enhance the efficient of energy-savings will be reduced by Using assistant cooling composite ground source heat pump system.This paper introduces the climate and the overview of building energy consumption of hot summer and cold winter region and analyses the feasibility of ground source heat pump system using assistant cooling equipment in this region.Taking a building in Shanghai for example,the initial investment and operating cost between assistant cooling composite ground source heat pump system and no assistant cooling ground source heat pump system are compared.The results show that the assistant cooling-source heat pump system has great advantages in the reduction of initial investment and operating cost in this region.