    摘要:

    对地源热泵相变蓄能地板辐射采暖技术与其它供暖方式进行了比较,指出此系统的优点;还将低温热水与电热源两种方式从环境效益方面论证地源热泵低温热水提供热量的可行性,分析了供水温度、相变温度与相变半径、相变材料的填充量以及盘管间距各因素的影响,同时与目前常用的电加热方式进行了经济性分析,年运行费用不到电加热的1/3。

    Abstract:

    It was proven that the heating way with low temperature water has many advantages through the comparison of the GSHP radiant floor heating system with PCM and other heating modes.Besides the floor radiant heating system with low water and electricity were also compared from the exergy consumption in this paper,it was demonstrated that the radiant floor heating with low temperature water is the optimum.Also the paper had analyzed the influences of water supply temperature,phase transition temperature and phase change radius,filling amount of PCM and coiled pipe spacing.The author compared this heating mode with the mordern heating modes with electricity from the economical aspects.The results show that its anhual operation cost is less then 1/3 of the heuting with electricity.