基于建筑负荷窗墙比与遮阳优化设计研究
DOI:
作者:
作者单位:

作者简介:

通讯作者:

中图分类号:

基金项目:


Study on window一wall ratio and shading based on simulation and examination of building load
Author:
Affiliation:

Fund Project:

  • 摘要
  • |
  • 图/表
  • |
  • 访问统计
  • |
  • 参考文献
  • |
  • 相似文献
  • |
  • 引证文献
  • |
  • 资源附件
  • |
  • 文章评论
    摘要:

    以典型气象条件为基础,对重庆地区建筑空调负荷随窗墙比的变化关系作出了模拟分析,结合采光、美观和施工等因素,采用分配权重的方法得到了重庆地区东西窗墙比的设置应当介于0.342-0.352之间为优;而南北窗墙比的设置应当介于0.375-0.385之间为优。通过遮阳测试结果,并结合美观和设计施工等因素时,综合认为板宽值取在0.6-0.8 m之间即认为是最优。

    Abstract:

    Based on the typical weather conditions of Chongqing city, the changing of building load varying with window-wall ratio has been analyzed. Combining with the factors of lighting, beauty, and construction, and utilizing the weight method, the window一wall ratio of eastern and western within 0. 342 to 0. 352 is excellent, and within 0. 375 to 0. 385 of southern and northern is excellent. By shading experiment result, and combining with the factors of scalar lighting, beauty, and construc- lion, the width of shading device within 0. 6 to 0. 8 meter is excellent.

    参考文献
    相似文献
    引证文献
引用本文

张华民,许秀梅,张甫仁.基于建筑负荷窗墙比与遮阳优化设计研究[J].河北工程大学自然版,2012,29(2):41-44