Design and elastic-plastic ultimate bearing capacity analysis of pre-stressed truss
DOI:
CSTR:
Author:
Affiliation:

Clc Number:

Fund Project:

  • Article
  • |
  • Figures
  • |
  • Metrics
  • |
  • Reference
  • |
  • Related
  • |
  • Cited by
  • |
  • Materials
  • |
  • Comments
    Abstract:

    The roof of the gym is a typical pre-stressed steel truss.It mainly introduced the structure layout.With initial pre-stress and static analysis,the effective method to use the pre-stress was given.Considering initial imperfection,the geometry nonlinear calculation and elastic-plastic ultimate load capacity analysis are taken,and then the damage mechanism was got.The results show that the structure has enough safety emergence capacity.

    Reference
    Related
    Cited by
Get Citation

SUN Wei. Design and elastic-plastic ultimate bearing capacity analysis of pre-stressed truss[J].,2009,26(1):46-50

Copy
Related Videos

Share
Article Metrics
  • Abstract:
  • PDF:
  • HTML:
  • Cited by:
History
  • Received:December 24,2008
  • Revised:
  • Adopted:
  • Online: January 12,2015
  • Published:
Article QR Code